The DC92 has been designed for direct current loads, particularly motors as used on small electric vehicles such as light industrial trucks. Developed for both interrupted and uninterrupted loads, the DC92 is suitable for switching Resistive, Capacitive and Inductive loads.
The DC92 features double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity. The DC92 is a monoblock construction, resulting in a neat compact design which is compatible with modern electronic control systems. The M8 stud main terminals can be configured in a variety of ways in order to suit the application. Supplied with a mounting bracket as standard, or alternatively supplied with M4 tapped holes. Mounting can be horizontal or vertical, when vertical the M8 contact studs should point upwards. If the requirement is for downwards orientation we can adjust the contactor to compensate for this.
Application | ||
Thermal Current Rating | 100A | 125A |
Intermittent Current Rating: | ||
30% Duty | 185A | 230A |
40% Duty | 160A | 200A |
50% Duty | 140A | 175A |
60% Duty | 130A | 160A |
70% Duty | 120A | 150A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: (In accordance with UL583*) | ||
Blowouts | 800A at 80V D.C. | |
No Blowouts | 800A at 48V D.C. | |
Rated Fault Current Breaking Capacity (Icn) Resistive Load: (In accordance with UL508*) | ||
Blowouts | - | |
No Blowouts | - | |
Maximum Recommended Contact Voltages | ||
Blowouts | 96V | 96V |
No Blowouts | 48V | 48V |
Typical Voltage Drop per pole across New Contacts at 100A | 40mV | |
Mechanical Durability | > 5,000,000 Cycles | |
Coil Voltage Available (Us) (Rectifier board required for A.C.) | 6 - 240V |
Component | Configurations |
---|---|
Auxiliary |
STANDARD
STANDARD - GOLD
|
Coil Suppression |
DIODE
DIODE AND RESISTOR
BI-DIRECTIONAL DIODE
|
Coil Terminations |
AMP TAGS
FLYING LEADS
VACCUM IMPREGNATION
|