Close

DC64P

NO - DP - ST - IP67

The DC64P has been designed for direct current loads, such as motors used on small winches.  The DC64P is a monoblock construction, resulting in a compact design which is compatible with modern electronic control systems.  Devised for both interrupted and uninterrupted loads, this contactor is suitable for switching Resistive, Capacitive and Inductive loads.

The DC64P has double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity.  The ‘P type configuration offers greater environmentally protected switches, compliant to IP66.  The DC64P has M6 main stud terminals and coil connections are by means of 6.3mm spades.

 

DC64P Technical Information

Application
InterruptedRating ( Ith )Uninterrupted
Thermal Current Rating 80A 80A
Intermittent Current Rating:
30% Duty 145A 145A
40% Duty 125A 125A
50% Duty 115A 115A
60% Duty 105A 105A
70% Duty 95A 95A
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: (In accordance with UL583*)
Blowouts -
No Blowouts 500A at 60V D.C.
Rated Fault Current Breaking Capacity (Icn) Resistive Load: (In accordance with UL508*)
Blowouts -
No Blowouts 120A at 48V D.C.
Maximum Recommended Contact Voltages
Blowouts - -
No Blowouts 48V 48V
Typical Voltage Drop per pole across New Contacts at 80A 40mV

Mechanical Durability > 3,000,000 Cycles
Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 130V

DC64P Features

Component Configurations
Coil Suppression
DIODE
DIODE AND RESISTOR
BI-DIRECTIONAL DIODE
Coil Terminations