Application | ||
Thermal Current Rating | 250A | 350A |
Intermittent Current Rating: | ||
30% Duty | 455A | 640A |
40% Duty | 395A | 555A |
50% Duty | 355A | 495A |
60% Duty | 325A | 450A |
70% Duty | 300A | 420A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: (In accordance with UL583*) | ||
Blowouts | 1500A at 80V D.C. | |
No Blowouts | 1500A at 48V D.C. | |
Rated Fault Current Breaking Capacity (Icn) Resistive Load: (In accordance with UL508*) | ||
Blowouts | 525A at 96V D.C. | |
No Blowouts | 525A at 48V D.C. | |
Maximum Recommended Contact Voltages | ||
Blowouts | 96V | 96V |
No Blowouts | 48V | 60V |
Typical Voltage Drop per pole across New Contacts at 250A | 40mV | |
Mechanical Durability | > 3,000,000 Cycles | |
Coil Voltage Available (Us) (Rectifier board required for A.C.) | 6 - 240V |
Component | Configurations |
---|---|
Auxiliary |
STANDARD
STANDARD - GOLD
V3
V3 - GOLD
|
Coil Suppression |
DIODE
DIODE AND RESISTOR
BI-DIRECTIONAL DIODE
|
Coil Terminations |
AMP TAGS
FLYING LEADS
PLUG
VACCUM IMPREGNATION
|
Mounting Options |
Top Hat Bracket Kit
'L' Shaped Bracket Kit
M5 Tapped Holes
|
Aïe ! Nous n’avons pas retrouvé votre formulaire.