SW215

SP - DT - NORMALLY CLOSED ON STUD CONTACTS

The SW215 has been designed for direct current loads, including motors as used on electric vehicles such as industrial trucks.  Developed for both interrupted and uninterrupted loads, the SW215 is suitable for switching Resistive, Capacitive and Inductive loads.

SW215 Technical Information

Application
InterruptedRating ( Ith )Uninterrupted
Thermal Current Rating 250A 250A
Intermittent Current Rating:
30% Duty 455A 455A
40% Duty 395A 395A
50% Duty 355A 355A
60% Duty 325A 325A
70% Duty 300A 300A
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: (In accordance with UL583*)
Blowouts 1500A at 96V D.C.
No Blowouts 1500A at 48V D.C.
Rated Fault Current Breaking Capacity (Icn) Resistive Load: (In accordance with UL508*)
Blowouts -
No Blowouts -
Maximum Recommended Contact Voltages
Blowouts 96V -
No Blowouts 48V -
Typical Voltage Drop per pole across New Contacts at 250A 40mV

Mechanical Durability > 5,000,000 Cycles
Coil Voltage Available (Us) (Rectifier board required for A.C.) 6 - 240V

SW215 Features

Component Configurations
Auxiliary
STANDARD
STANDARD - GOLD
V3
V3 - GOLD
Coil Suppression
DIODE
DIODE AND RESISTOR
BI-DIRECTIONAL DIODE
Coil Terminations
AMP TAGS
FLYING LEADS
VACCUM IMPREGNATION

Aïe ! Nous n’avons pas retrouvé votre formulaire.