The SW150 is designed for use in telecommunications and power distribution applications where an uninterrupted current load is switched. These contactors are primarily for use with Direct Current loads but can also be used with Alternating Currents.
The SW150 features double breaking main contacts with silver alloy tips which are weld resistant, hard wearing and have excellent conductivity. Silver plating on the main contacts is standard for the SW150, however optionally it can be excluded from the specification. The SW150 is a compact contactor which can be busbar mounted vertically or horizontally, if mounted vertically the coil should be at the bottom. If the coil is required at the top, we can adjust the contactor to compensate for this.
アプリケーション(用途) | ||
熱電流定格 | - | 150A |
断続的な電流定格 | ||
30% デューティ | - | 275A |
40% デューティ | - | 235A |
50% デューティ | - | 210A |
60% デューティ | - | 195A |
70% デューティ | - | 180A |
定格故障電流遮断容量(Icn)5ms時定数: (UL583 *に準拠) | ||
ブローアウト | - | |
ブローアウト無し | - | |
定格故障電流遮断容量(Icn)抵抗負荷: (UL508 *に準拠) | ||
ブローアウト | - | |
ブローアウト無し | 225A at 60V D.C. | |
最大推奨接点電圧 | ||
ブローアウト | - | - |
ブローアウト無し | - | 60V |
新しい接点での極ごとの一般的な電圧降下150A | 50mV | |
機械的耐久性 | > 1,000,000 Cycles | |
使用可能なコイル電圧(Us)(ACには整流器ボードが必要です) | 6 - 240V |
構成 | 構成 |
---|---|
補助 |
|
コイル・サプレッション |
|
コイル終端 |
|
取り付けオプション |
|